| TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-1. Test Equipment Required (Sheet 3 of 3)
TEST EQUIPMENT
TEST CHARACTERISTICS
Oscilloscope MIL-O-9960C
Dc: 0 to 150 V.
Ac: 0 to 200 mV peak-to-peak.
Display modulation envelope
Rf frequency: 2 MHz.
Modulation frequency: 1000 Hz.
Modulation: 0 to 100%.
Amplitude, vertical: 0.1 V/cm.
Horizontal sweep: 0.5 ms/cm.
Fluke 8000A-01 Digital Multimeter
Audio: 0 to 1 V rms + 3%.
Dc: 0 to 10 V dc + 1%, 0 to 26 V dc + 2%, 0 to 100 V dc 10%,
0 to -4 V dc 1%, 0 to -12 V dc 4%.
HP 10514A Double Balanced Mixer
Frequency: 225 to 400 MHz.
Modulation: 0 to 100%.
Input: 40 mA maximum.
Power: 5 mW nominal.
HP 6299A with Option 09 Power Supply
Voltage output: 0 to 100 V dc.
Current output: 0 to 750 mA.
Input voltage: 115 V ac.
Input frequency: 48 to 440 Hz.
Input current: 1.5 A.
Power consumption: 135 W.
Handset H-169U
Transmitter: Low impedance, dynamic.
Receiver: Impedance 600 ohms.
Table 5-2. Test Points (Sheet 1 of 4)
REFERENCE
MODULE TO WHICH
DESIGNATION
TEST POINT
FUNCTION
TEST POINT APPLIES
TEST meter
FWD PWR
Provides indication of transmitter
Rf filter A7 and power amplifier A8
A10A1M1
forward power. Power will be 16
to 24 watts for antenna vswr of
3:1 or less.
5-3
|