Click here to make tpub.com your Home Page

Page Title: Test Procedure
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-695-35
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
1
None.
1054(P)A/GRC-144(V)
Bandpass filter
1FL3 set to 4900
MHz Modulator 1A8
S1O1: 15 GHz
S102: 14.7-15 GHz
Frequency Synthesizer-
1A14 Thumb-
wheel Switches
4900.0 MHz Converter-
Multiplier CV-
3633/GRC-144(V)
Bandpass Filter
3A3:14.8 GHz
3A4:14.7 GHz
NOTE
For the AN/GRC-144
(V)4 optional con-
figuration set Switch
Waveguide SA-1679/GRC
to the TO ANTENNA
(NORMAL) position.
N/A
Set transmit
The status panel
waveguide
SUMMARY ALARM
switch to
the 15 GHz
T-1054(P)A/GRC-
OPERATE -
144(V) CNTRL
position.
ALARM indicators
shall illuminate
red and audible
alarm shall sound.
If the alarm
indications do not
occur proceed to
step 2 and perform
the reflected alarm
adjustment range
procedures and re-
peat step 1.
2. Same as step 1. None
a. Remove test
a. None.
lead from the
mount in the
R-1467(P)A/GRC
-144(V) SPECIAL
TOOLS AND SPARE
FUSES compartment
Change 6
3-107