| TM 11-5820-695-35
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
1
None.
Transmitter T-1054
1054(P)A/GRC-144(V)
Bandpass filter
1FL3 set to 4900
MHz Modulator 1A8
S1O1: 15 GHz
S102: 14.7-15 GHz
Frequency Synthesizer-
1A14 Thumb-
wheel Switches
4900.0 MHz Converter-
Multiplier CV-
3633/GRC-144(V)
Bandpass Filter
3A3:14.8 GHz
3A4:14.7 GHz
NOTE
For the AN/GRC-144
(V)4 optional con-
figuration set Switch
Waveguide SA-1679/GRC
to the TO ANTENNA
(NORMAL) position.
N/A
Set transmit
The status panel
waveguide
SUMMARY ALARM
switch to
and Transmitter
the 15 GHz
T-1054(P)A/GRC-
OPERATE -
144(V) CNTRL
position.
ALARM indicators
shall illuminate
red and audible
alarm shall sound.
If the alarm
indications do not
occur proceed to
step 2 and perform
the reflected alarm
adjustment range
procedures and re-
peat step 1.
2. Same as step 1. None
a. Remove test
a. None.
lead from the
mount in the
R-1467(P)A/GRC
-144(V) SPECIAL
TOOLS AND SPARE
FUSES compartment
Change 6