| TM 11-5820-695-35
3-29.1. Replacement of Digital Data Combiner lA12
TM 11-5820-695-35 (8) As viewed from the front, slowly
push digital data combiner chassis from its position
inside cover.
a. Removal.
b. Replacement.
(1) Set the POWER ON/OFF Switch on
meter panel assembly lA15A8 to OFF.
(1) Insert replacement digital data combiner
(2) Disconnect cable assemblies lA15W28
lA12 chassis inside cover by carefully pushing chassis
and lA15W29 connectors 1lA15P4 and lA15P5 from the
into cover at the rear of cover until holes on bottom of
digital data combiner 1A12.
cover mate with holes at bottom of chassis.
(2) Secure digital data combiner 1A12 cover
CAUTION
and chassis together using four screws at bottom and
Do not loosen one captive screw
four screws at rear of cover removed in a(6) and a(7).
completely at one time. Completely
(3) Carefully insert plug-in components
loosening one assembly captive
lA12Al through lA12A8, removed in a(5) into their
screw at a time may damage the
respective positions as indicated on the hinged cover of
digital data combiner.
1A12.
(4) Close the hinged front cover and tighten
(3) Loosen the two assembly captive screws
the three cover captive screws securing the hinged front
securing digital data combiner 1A12 to electrical
cover.
equipment cabinet lA15 by alternately turning each
(5) Insert replacement digital data combiner
captive screw two turns at a time until the captive screw
into electrical equipment cabinet lA15.
turns freely. Withdraw Digital data combiner 1A12 from
electrical equipment cabinet 1A15.
(6) Alternately tighten each assembly captive
screw a few turns each until the digital data combiner
(4) Loosen the three cover captive screws
1A12 is firmly seated in the electrical equipment cabinet
securing the hinged front cover and lower cover.
lA15.
(5) Using a card extractor carefully remove
(7) Reconnect cable assemblies lA15W28
plug-in components lA12A1 through lA12A8 from the
and 1A15W29 connectors 1A15P4 and 1A15P5 to
digital combiner : hassis.
digital data combiner jacks J1 and 32 respectively.
(6) Remove four screws on rear : over and
(8) Set the POWER ON/OFF switch on meter
remove cover.
panel assembly 1A15A8 to ON.
(7) Remove four screws on bottom of Digital
data combiner case.
Change 6
3-50.3/(3-50.4 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |