| TM 11-5820-695-35
Item No.
Symptom
Probable trouble
Corrective actions
32 Cannot calibrate the LOCAL
Defective component or wire in metering
Remove amplifier-mixer 2A7 and check
OSC POWER section of the
circuit.
resistance between pin 8 of connector
R-1467(P)/GRC-144(V) and
2A16XA7 and pin 27 of 2A15A2S1B
R-1467(P)A/GRC-144(V) local
(fig. 6-21). Note that resistance
oscillator power metering
varies smoothly from zero to 5,000
circuits (para 3-65).
ohms as potentiometer 2A15A2R5
to the other. Also check for continuity
between pin 9 of connector 2A16XA7
and pin 27 of 2A15A2S1A.
33 Cannot calibrate the FREQ
Defective component or wire in metering
Remove frequency mixer stage 2A8
MIXER CURRENT 1 sec-
circuit.
and check resistance between pin
tion of the R-1467(P)/GRC-
9 of connector 2A16W1XA8 and pin
144(V) and R-1467(P)AGRC-
11 of 2A15A2S1A (fig. 5-21).
144(V) local oscillator meter-
Note that resistance varies smoothly
ing circuits (para 3-65)
from zero to 50,000 ohms as
potentiometer 2A15A2R3 (fig. 3-18)
is varied from one extreme to the
other. Also check for continuity
between pin 11 of 2A15A2S1B and
the E2 CAB GRD lug on top of 2A15.
34 Cannot calibrate the FREQ
Defective component or wire in metering
Remove frequency mixer stage 2A8
MIXER CURRENT 2 sec-
circuit.
and check resistance between pin
tion of the R-1467(P)/GRC-
9 of connector 2A16W1XA8 and pin
144(V) and R-1467(P)A/GRC-
13 of 2A15A2S1A (fig. 5-21).
144(V) local oscillator meter-
Note that resistance varies smoothly
ing circuits (para 3-65)
from zero to 50,000 ohms as
potentiometer 2A15A2R4 (fig. 3-
18) is varied from one extreme to
the other. Also check for continuity
between pin 13 of 2A15A2S1B and
the E2 CAB GRD lug on top of 2A15.
35 Cannot calibrate the MULT-
Defective component or wire in metering
Remove frequency multiplier-osc
OSC section of the R-1467(P)/
circuit.
2A13 and check resistance between
GRC-144(V) and R-1467(P)A/
pin 9 of connector 2A16W1XA13
GRC -144N(V) local oscillator
and pin 15 of 2A15A2S1B (fig.
metering circuits (para 3-65)
5-21). Note that resistance vanes
smoothly from zero to 5,000 ohms as
potentiometer 2A15A2R6 (fig. 3-18)
is varied from one extreme to the
other. Also check for continuity pin
15 of 2A15A2S1A and the E2 CAB
GRD lug on top of 2A15.
(2)
Remove switch 2A15A2S2 protective
3-13. Isolating Troubles in R-1467(P)/GRC-144(V) and
R-1467(P)A/GRC-144(V)
Primary
Power
cover (fig. 3-19) by removing the four nuts and two
Distribution Circuits
screws that secure it to meter panel assembly 2A16A2.
WARNING
(3)
Remove electrical frequency syn-
115 vac is present in R-1467(P)/GRC-
thesizer 2A14 (para 3-49).
144(V) Do not perform any of the
b.
Procedure.
continuity or resistance checks given
(1)
Refer to the chart (c below). Connect
in
this
paragraph
while
the
the multimeter leads between the two pins listed in the
equipment is connected to the
steps of the sections that were referenced in the
primary power source.
troubleshooting chart (para 3-12c). If the trouble-
a.
Preparation of R-1467(P)/GRC-144(V) and
shooting chart indicates a section but does
R-1467(P)AGRC-144(V).
(1) Remove power supply 2A1 (para 3-40).
Change 6 3-25
|