|
| TM 11-5820-695-35
opens deenergizing air flow fault relay 3A1K2. If the air
CV-3633/GRC-144(V) modules through the various
flow fault relay is energized because of adequate air
terminal board and connector pins shown in figure 2-33
flow or deactivated by thermostat 3A7S1 when the CV-
and is used to provide the bias voltages for transistor
3633/GC-144(V) operating temperatures; are above
and integrated circuit operation, closure voltage for relay
approximately 158 (70 ); the status panel lamp
F
C
operation, illuminates all monitor and fault indicators
3A80S2 illuminates AIR FLOW fault indicator monitor
and provides operating voltage for electronic frequency
green. When the air flow fault relay is deenergized
converter tunnel diode amplifier 3A2A1 and local
because of inadequate air flow the status panel lamp
oscillator 3A2A3. The +28 Vdc is also switched by
3A80S4 illuminates AIR FLOW fault indicator monitor
amplifier-multiplier 3A5 thermostat 3A5S2 to illuminate
red. Refer to paragraph 3-87 for a complete description
status panel 3A8 TEMP indicator green or red indicating
of alarm monitor 3A1 circuit functioning.
amplifier-multiplier 3A5 temperature normal and alarm
conditions respectively. In addition, the air flow sensing
switch 3A7S2 heating element is powered by +28 Vdc
d. Mounted on the electrical equipment chassis
through rfi filters 3A7FL4, 3A7FL5 and 3A7FL8 that
3A7 are the necessary components to rf couple
prevent unwanted interference of electromagnetic
operating modules of the CV-3633/GRFC-144(V) and
antenna system together (fig. 2-34). The transmit and
of thermostat 3A7S1, air flow sensing switch 3A752, or
receive paths from Transmitter, Radio T-1054(P)A/IRC-
status panel 3A8 OSC TEMP indicator PUSH TO TEST
144 and Receiver, Radio R-1467(P)A/GFC-144 to and
switch 3A8DS1.
from the antenna system through the electrical
equipment chassis 3A7 components are described in (1)
c. Under ambient operating temperatures and
and (2) below.
temperatures below approximately 140 F (60 C),
thermostat 3A7S1 is closed applying +28 Vdc to a
(1) The C-band 4.8 to 5.0 GHz output from
heating element in air flow sensing switch 3A7S2.
Transmitter, Radio T-1054(P)A/GRC-144 is applied to
When the air flow sensing switch 3A7S2 temperatures
the CV-3633/GRC-144(V) amplifier multiplier 3A5
are maintained by adequate air flow from the R-
circuits. Amplifier multiplier 3A5 is a fixed tuned
1467(P)A/GRC-144 blower 2A1561, airflow sensing
broadband amplifier that contains a X3 multiplier 3A5A1
switch is closed applying +28 Vdc to alarm monitor 3A1
and impatt amplifier circuits and a constant current
air flow fault relay 3A1K2 through rfi filter FL8-A3 and
source 3A5A8. The amplifier-multiplier circuits up-
connector 3AXAl pin 14. If adequate air flow from
convert the 4.8 to 5.0 GHz
blower 2Al581 is not maintained, air flow sensing switch
Change 6 2-127
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |