| TM 11-5820-695-35
lamp DS2 in 1A12A4 is lighted green and the alarm
R19 is applied through bias/current limiting resistors R20
signal output (radio repeater pcm failure, 1RRPFAIL) is
and R21 to the bases of transistors Q3 and Q4.
deactivated. If the retimed pcm signal is not detected,
Transistor Q3 is turned on and the ONOR output signal
the alarm circuit causes the green indicator lamp to go
is logic 0 (normal) because the +12vdc supply voltage is
out and activates
the failure signal (1RRPFAIL)
dropped across the collector load CR9 and R23
which is applied to alarm monitor 1A12A5 or 1A12A15.
Transistor Q4 also turns on, lamp DS1 turns on and
signal 1RPFAIL is logic zero (normal). If there is no
traffic activity, there is no voltage output from the
rectifier and transistors Q1 through Q4 are all off.
orderwire signal (FRPCM) is recovered in radio
Signal ONOR is then logic 1 (alarm) and signal
amplifier-detector 1A12A7 The orderwire output signal
1RPFAIL is logic 1 (alarm). When Q4 is off, resistor
(RRW) from 1A12A7 is sent to orderwire assembly
R22 allows a small current to flow through lamp DS1 to
1A13 where it is distributed to the orderwire stations and
keep the filament warm. This reduces the current surge
routed back (cable ow in CCWIN) to af amplifier
in Q4 caused by lighting of DS1 when Q4 turns on
1A12A6 The amplified output of 1A12A6 (cable transmit
d. Cable Digital Processor 1A12A4 (fig. 5-8 and 5-
ow, CCTW) is applied to the primary of transformer
32) The radio-to-cable circuits portion of cable digital
1A12A12A2T2. The direct current path from the cable-
processor 1A12A4 is used only in the radio repeater
to-radio circuits is completed through the normally
mode of operation Cable digital processor 1A12A4
closed
contacts
of
the
fault
locator
relay
receives the retimed pcm (1RPCM) signal from radio
(1A12A12A2TBlK1) The fault locator relay is normally
control-comparator 1A12A9 and converts the 1RPCM
energized by a ground from the CABLE LOOP TEST
signal from standard logic levels to the levels required
switch (NORMAL position) or by a control signal (ON
by the input circuits of Transmitter,
Radio T-
R) from radio digital processor 1A12A10. When the
1054/GRC-144.
CABLE LOOP TEST switch is in NORMAL position,
fault locator relay Is energized; when the CABLE LOOP
(1) The retimed radio-to-cable pcm signal
TEST switch is in TEST position the fault locator relay is
(1RPCM) is applied through digital buffer 2 to level
deenergized. The position of the CABLE LOOP TEST
converter 2 and to alarm circuit 2 The level converter
switch determines the mode of operation of the cable-to-
(R9, R10, R11) converts the signal voltages to the levels
radio circuits of cable digital processor 1A12A4 (para 2-
required by the modulator circuits of Transmitter, Radio
5c), the radio-to-cable circuits of alarm-monitor 1A12A5
T-1054/GRC-144. The output signal, radio repeat pcm
or 1A12A15 (h below), and radio digital processor
(1RRPCM), is applied to the RADIO REPEATER
1A12A10 or 1A12A16. The effect of the CABLE LOOP
OUTPUT connector.
TEST switch on the operation of 1A12A10 or 1A12A16
(2) Alarm circuit 2 monitors the retimed pcm
is explained in c(3)(c) above; this information in relation
signal from the digital buffer. Operation of alarm circuit
to the relay to summarized in the following chart.
2 is similar to operation of alarm circuit 1, described in
CABLE LOOP
TEST
pcm
IA12A10 or IA12A16
switch position
traffic
ONOR
IRPFAIL
Relay
output signal
NORMAL ............... normal ................ logic zero ............ logic zero................energized ................... radio-to-cable pcm
Test........................ normal ................ logic zero ............ logic zero................not energized ............. cable loop-back
pcm
NORMAL ............... failed................... logic one............. logic one.................energized ................... no pcm
TEST ..................... failed................... logic one............. logic one.................not energized ............. cable loop-back
pcm
With the fault locator relay deenergized, the
pcm/dc/orderwire (FRPCM) signal from Receiver, Radio
resistor/capacitor/diode network on terminal board
R-1467/GRC-144 and the reshaped pcm signal
1A12A12A2TB1 is switched into the direct current path
(1RSPCM-2) from 1A12A8. The function of 1A12A7 is
and provides fault localizing information to Multiplexer
to recover the orderwire signal from the FRPCM signal
TD-204/U at the other end of the cable system.
(that is, eliminate the pcm component) and provide an
amplified orderwire signal as output The basic method
used to accomplish this purpose is to
Change 2 2-20.2
|