| TM 11-5820-670-30
2-79. VOLUME CONTROL SWITCH R 9103 REPLACEMENT. (CONT)
NOTE
Discard attached resistor along with defective switch.
INSTALLATION
NOTE
Before attempting to install switch in control panel, a specified value resistor must be
soldered between terminals as shown in detail A.
Insulation must be installed on both wire leads of resistor prior to soldering (step 1).
1. Install insulation (10) on both wire leads of resistor (11) as shown in detail B.
2. Solder both wire leads of resistor (11) as shown in detail A.
3. Solder one white and white wire (9), one white and brown wire (8), and one black wire (7) to
switch (5).
NOTE
When performing next step ensure locating tab on switch is in locating hole behind
control panel.
4. Position switch (5) in control panel (6) and install IT Iockwasher (4) and nut (3) and, using
wrench, tighten nut (3).
5. Install cover (2) and, using screwdriver, tighten two turn-lock fasteners (1).
FOLLOW-ON MAINTENANCE: Install light panel (para 2-76).
2-231
|