| TM 11-5820-670-30
2-43. A3000 MODULES AND ASSEMBLY REPLACEMENT. (CONT)
INSTALLATION (CONT)
CAUTION
Before installing modules, ensure pins are not bent. Straighten any bent pins. Extreme
care must be taken not to damage pins.
Modules A3100 through A3700 are secured with captive screws. Steps 5 and 6 are typ-
ical for all modules.
Module location is stamped on board.
5. Carefully position module (1) on pins (2) and push into place.
6. Using screwdriver, tighten captive screws (3).
7. Connect black wire (P3301) (4) to A3300 (5), red wire (P3701) to A3700 (6), green wire
(P3002) (7) to FL3002 (8), and all wires to wire clips.