2-36. LOCAL OSCILLATOR ALINEMENT.
TEST EQUIPMENT AND MATERIALS
Maintenance Kit MK-1035/ARC-131
Power Supply PP-2953/U
Frequency Meter AN/USM-207
T-Connector
All cables are part of MK-1035/ARC
TEST SETUP
Connect equipment as shown in test setup diagram. Turn on all equipment and allow at least 5 minutes
for warmup.
EL1AT247
ALINEMENT PROCEDURE
1. Set control unit mode switch to T/R.
2. When RT-823/ARC-131 is on a frequency range of 30.00 to 52.95 MHz, frequency counter will
read that frequency plus 11.5 MHz. When RT-823/ARC-131 is on a frequency range from 53.00
to 75.95 MHz, the frequency counter will read that frequency minus 11.5 MHz. See the following
table.