2-35. RECEIVER SENSITIVITY ADJUSTMENTS. (CONT)
13. Change frequency to 75.00 MHz and repeat step 10, tuning 65.00 and 75.00 MHz coils using
a nonmetallic alinement tool.
14. With frequency at 75.00 MHz, repeat step 10, tuning the 65.00 and 75.00 MHz capacitors
using a small jeweler's screwdriver.
15. If tests are still unsuccessful, substitute boards as necessary and repeat alinement procedures,
or refer radio to higher level of maintenance.
EL1AT246
16. If a distorted signal is observed, perform steps 17 through 23.
17. Attach CG-3376/U from J107 on test set to INPUT of oscilloscope.
18. Connect test set to RT-823/ARC-131 with J117.
19. Use CG-3370/U to connect Signal Generator AN/URM-103 (LO-RF) to test set at J112.
20. Set control unit and signal generator to corresponding frequencies.
21. Set control unit mode switch to T/R.
22. Using screwdriver, unscrew if. amplifier board A4000 and lift up to gain access to two variable
coils on the side.
23. With a nonmetallic alinement tool, adjust the two coils while observing signal on oscillo-
scope. Adjust slowly and observe signal to adjust its symmetry.