2-32. 150 Hz TONE MODULATION FREQUENCY AND DEVIATION ADJUSTMENT.
TEST EQUIPMENT AND MATERIALS
Maintenance Kit MK-1035/ARC-131
Electronic Counter Digital Readout AN/USM-207
Modulation Meter ME-57/U
Power Supply PP-2953/U
All cables are part of MK-1035/ARC
TEST SETUP
Connect equipment as shown in test setup diagram. Turn on all equipment and allow at least 5 minutes
for warmup.
EL1AT148
ADJUSTMENT PROCEDURE
1. Place +28 VDC ON-OFF switch on TS-2575/ARC-131 to ON.
2. Place XMTR HI-LO switch on receiver-transmitter to LO.
3. Set WIDE BAND - NARROW BAND switch on TS-2575/ARC-131 to NARROW BAND.
4. Set control unit mode switch to T/R, VOL control fully clockwise, SQUELCH switch to
TONE, and frequency selectors to 80.05 MHz.
5. Set RF AMP ALIGN HI-LO switch on TS-2575/ARC-131 to LO.
2-136