| TM 11-5820-554-12
ELOC0033
Figure 10-6. View graph for forward versus reflected power.
Table 10-2. Operation of Phone Patch and Function Switches
Function
switch
Phone patch switch positions
position
On
Off
Station mute
NORMAL
Speaker dead, MIC dead, PTT
Speaker live, MIC live, PTT operative,
Speaker dead, MIC dead, transmitter
operative, VOX operative, patch
VOX operative, patch disconnected.
input grounded*, PTT inoperative.
connected.
RECEIVE ONLY
Speaker dead, transmitter input
Speaker live, PTT inoperative,
Same as above.
grounded*, PTT inoperative, MIC
transmitter input grounded*, patch
dead, patch hears receiver.
disconnected.
TRANSMIT ONLY
Speaker dead, PTT operative, MIC
Speaker dead, PTT operative, MIC live,
Same as above.
dead, antivox voltage grounded.
antivox voltage grounded.
*PHONE PATCH OUT jack (J4) shorted.