TM 11-5820-554-12
Section III.
POWER SUPPLY PP-4765/GRC-1 59(V)
Low voltage
265 volts , 210 ma.
7-13. Description
High voltage
750 volts,185 ma.
Power Supply PP - 4765/GRC-159(V) (Collins 516E2)
Output regulation:
converts d.c. energy from the automobile storage
Low voltage
290 volts maximum at 170 ma.
battery (negative terminal ground) to B+ and bias
High voltage
860 volts maximum at 55 ma.
voltages necessary for operation of mobile amateur
690 volts minimum at 250 ma.
equipment such as the Collins KWM-2/ 2A. The PP
Ripple present on outputs:
765/GRC-159(V) may be used in a car, boat, or plane
Filament
Less than 2.5 volts peak to
having a 28-volt power system.
peak.
7-14. Tabulated Data
Bias
Less than 0.5 volt peak to
peak.
Input requirements:
Low voltage
Less than 0.2 volt peak to
Voltage.................. 24 to 30 volts, 28 volts nominal.
peak.
Current.................. Up to 15 amp
High voltage
Less than 10 volts peak to
Outputs (nominal):
peak.
Heater voltage ....... 24 volts, 2 1/2 amp.
Efficiency
Approximately 80%.
Bias voltage........... -50 to -80 volts (adjustable).
Operating temperature
-30C. to +60C
Low voltage .......... 265 volts, 210 ma.
Humidity
0 to 90% at 50C. for
High voltage ......... 750 volts, 185 ma.
48 hours.
Output regulation:
Heater voltage
24 volts, 2 amp.
Bias voltage
-50 to -80 volts (adjustable).
EL0D0018
Figure 7-7. Interconnections to Collins KWM-2/2A.
7-7