TM 11-5820-518-20
be reported to higher category maintenance
WARNING
personnel. Records and reports of preventive
Adequate ventilation should be provided
maintenance must be made in accordance with
while using TRICHLOROTRIFLUORO-
procedures given in TM 38-750.
ETHANE. Prolonged breathing of vapor
should be avoided. The solvent should
3-4. Organizational Intermediate and Periodic
not be used near heat or open flame; the
Preventive Maintenance Checks and
products of decomposition are toxic and
Services
Since TRICHLOROTRI-
irritating.
a. General. Perform the maintenance func-
FLUOROETHANE dissolves natural oils,
tions indicated in the intermediate preventive
prolonged contact with skin should be
maintenance checks and services chart (para 3-5)
When necessary, use gloves
avoided.
every 25 flying hours (concurrently with the
which the solvent cannot penetrate. If
aircraft intermediate preventive maintenance
the solvent is taken internally, consult a
checks and services to reduce downtime). Refer
physician immediately.
to paragraph 3-10 (troubleshooting) for cor-
rective measures. Equipment that has a defi-
Compressed air is dangerous and c a n
ciency that cannot be remedied at the organi-
cause serious bodily harm if protective
zational category must be reported to higher
means or methods are not observed to
category maintenance personnel. Records and
prevent a chip or particle (of whatever
reports of Preventive Maintenance must be made
size) from being blown into the eyes or
in accordance with procedures in TM 38-750.
unbroken skin of the operator or other
b. Periodic Pullout Inspection. During the air-
personnel. Goggles must be worn at all
craft preventive maintenance checks and ser-
times while cleaning with compressed
vices,  the electronic  equipment (including
air. Compressed air shall not be used
the receiver-transmitter) will be removed from
for cleaning purposes except where
the aircraft for bench tests and inspections,
reduced to less than 29 pounds per
and replacement electronic equipments will be
square inch gage (psig) and then only
reinstalled from float stock. These tests and
with effective chip guarding and per-
inspections are performed by direct support
sonnel protective equipment. Do not
personnel. Perform the intermediate (para 3-5)
use compressed air to dry parts when
and periodic preventive maintenance checks
trichlorotrifluoroethane has been used.
and services after the float stock has been
c. Deficiencies that cannot be corrected must
installed.
3-5. Intermediate and Periodic Preventive Maintenance Checks and Services Chart
I Intermediate Preventive Maintenance Check
P - Periodic or Phased Preventive Maintenance Check
Interval
Item
Procedures
P
Item to be Inspected
No.
I
Check for completeness and satisfactory condition of the equipment.
Mission Essential
1
Report missing items.
Equipment
Check to see that pressure indicator (fig. 1-1) shows 3 to 5 psi
Pressure Indicator
2
internal air pressure in receiver-transmitter (center head of
indicator will protrude).
Remove and inspect air filter. Clean air filter in mild detergent and
External Blower Air
3
Filter
water. Dry and reinstall.
3-2
Change 5