TM 11-5820-509-35
Symbol
Description
Mfgr Part No.
Mfgr Code
Test Set for Radio Frequency Oscillator O-1032/PHC-47
DS1
Lamp (FSN 6240-196-4491)
330
08805
F1
Fuse (FSN 5920-043-2641)
F02A250V1 -4AS
J1
Connector (FSN 5935-089-1165)
DBMF13W3S
71468
Connector insert p/o J1 (FSN 5935-080-0268)
DM53742-5000
71468
J2
Connector
MS3102A24-28P
J3 thru J5
Connector (FSN 5935-755-2741)
UG912AU
M1
MillIiammeter, O-50 ma (FSN 6825-643-1527)
M531 -2-214
82386
R1
Resistor fixed, 100 ohms, 10%, 2 W
RC42GFIOlK
R2
Resistor fixed, 12,000 ohms, 10%, 1/2 W (FSN 5905-190
RC20GF123K
8884AHI
R3
Resistor, fixed, 510 ohms, 5%, 1/2 W (FSN 5906-279-3511)
RC20CF511J
R4
Resistor, fixed, 1200 ohms, 10%, 1/2 W (FSN 5905-195-6809)
RC20GP122K
S1
Switch (FSN 5930-855-1514)
ST42A
S2
Switch (FSN 5930417-7120)
MS25089-5C
DS1
Light (FSN 6210-825-20511
101-3830-9
72619
Lens p/o XDSI (FSN 6210-511 -82081
101-972
72819
XF1
Fuseholder (FSN 5920-284-71441
HKPH
71400
Note. All manufacturer 'a codes are 5-digit numbers . The corresponding manufacturer's name and address are listed in SB 708-42 Catalog Handbook
(H4-2).
circuit and the +20V ON-OFF switch is in the ON
6-22. Test Fixture for Oscillator Control C-
position.
4311/PRC-47
(3) +20V 1/2 AMP fuse.  This protective
device is connected to the +20 volts dc primary power
circuit to protect it from overload.
a. The test fissure for Oscillator Control C-
(4) ANTI-LOCX lamp. This lamp is lit when
4311/PRC-47 contains all switches, jacks and lamps
the anti-lock dc output from the module under test is
necessary to electrically test and adjust the module
present.
without providing a complete AN/PRC-47 Radio Set.
Power for the test fissure and the module under test is
(5) Coaxial connectors are provided for the
provided externally and is connected to the test fissure
connection of signal leads and test equipment and these
by a specially fabricated cable attached to power
are self-explanatory.
connector J4 at the rear of the test fixture.
c. The piece parts required for fabrication of the
b. The operating controls on the front panel of the
test fissure are listed in the following chart and
test fixture (fig. 6-10) perform the following functions:
suggested parts placement is shown in figure 6-27.
Schematic diagram (fig.  7-20) illustrates the internal
(1) +20V ON-OFF switch. This toggle switch
circuit of the test fixture.
controls the +20 volts dc primary power circuit to the
module under test.
d. Calibrate the Radio Frequency Oscillator 0
1032/PRC-47 used with this test fixture in accordance
(2) +20V lamp.  This indicator is lit when
with the procedures in paragraph 6-14g.
power is connected to the +20 volts dc primary power
6-56