(13) Rotate the switch-on the indexing fixture
continue
the
procedures
after
to 7 and set the receiver to 10.0 MHz.
performing  the  remaining  initial
setup instructions.
(14) Adjust capacitor C258 to provide a 10.000
MHz reading on the receiver (or frequency counter).
d. 5- to 14- MHz Ringer Circuit Alignment.
Readjust capacitor C258 for minimum 1-MHz ripple on
(1) Connect the oscilloscope and receiver (or
the oscilloscope wavetrain.  The remaining 10.0 MHz
frequency counter) and the multimeter rf probe to the 5-
wavetrain amplitude shall not be less than 0.9 volt peak-
14 MHz tip jack at the right side of the upper shelf of the
to-peak.
test fixture.
(15) Rotate the switch on the indexing fixture
(2) Set the switch on the indexing fixture (fig.
to 8 and set the receiver to 11.0 M Hz.
6-7) to 2, and the slug rack control to 000 position.
(16) Adjust capacitor C260 to provide an
(3) On the test fixture, place the POWER
11.000 MHz reading on the receiver (or frequency
ON-OFF switch to ON, the FUNCTION SEL switch to
counter}. Readjust capacitor C260 for minimum 1-MHz
RCVR, the AVC switch to ON, the LOOP SEL switch to
ripple on the oscilloscope wavetrain.  The remaining
CLOSED, and OSC CONT switches to 0 and 00.
11.0 MHz wavetrain amplitude shall not be less than 0.9
(4) Adjust capacitor C248 (fig.
volt peak-to-peak.
provide a 5.000 MHz reading on the receiver (or
(17) Rotate the switch on the indexing fissure
frequency counter) Set the oscilloscope sweep rate to
to 9 and set the receiver to 12.0 MHz.
1.0 microseconds/cm. and readjust capacitor C248 for
(18) Adjust capacitor C262 to provide a 12.000
minimum 1-MHz ripple (amplitude modulation) on the
MHz reading on the receiver (or frequency counter).
oscilloscope wavetrain.
The remaining 5.0 MHz
Readjust capacitor C262 for minimum 1-MHz ripple on
wavetrain amplitude shall be not less than 0.9 volts
the oscilloscope wavetrain.  The remaining 12.0 MHz
peak-to-peak.
wavetrain amplitude shall not be less than 0.9 volt peak-
(5) Rotate the switch on the indexing fixture
to-peak.
to 3 and set the receiver to 6.0 MHz.
(19) Rotate the switch on the indexing fixture
(6) Adjust capacitor C250 to provide a 6.000
to 10 and set the receiver to 13.0 MHz.
M Hz reading on the receiver (or frequency counter).
(20) Adjust capacitor C264 to provide a 13.000
Readjust capacitor C250 for minimum 1-MHz ripple on
MHz reading on the receiver (or frequency counter).
the oscilloscope wavetrain.  The remaining 6.0 MHz
Readjust capacitor C264 for minimum 1-MHz ripple on
wavetrain amplitude shall not be less than 0.9 volts
the oscilloscope wavetrain.  The remaining 13.0 MHz
peak-to-peak.
wavetrain amplitude shall not be less than 0.9 volt peak-
(7) Rotate the switch on the indexing fixture
to-peak.
to 4 and set the receiver to 7.0 MHz.
(21) Rotate the switch on the indexing fixture
(8) Adjust capacitor C252 to provide a 7.000
to 11 and set the receiver to 14.0 M Hz.
MHz reading on the receiver (or frequency counter).
(22) Adjust capacitor C266 to provide a 14.000
Readjust capacitor C252 for minimum 1-MHz ripple on
MHz reading on the receiver (or frequency counter}.
the oscilloscope wavetrain.  The remaining 7.0 MHz
Readjust capacitor C266 for minimum 1-MHz ripple-on
wavetrain amplitude shall not be less than 0.9 volt peak-
the oscilloscope wavetrain.  The remaining 14.0 MHz
to-peak.
wavetrain amplitude shall not be less than 0.9 volt peak-
(9) Rotate the switch on the indexing fixture
to-peak.
to 5 and set the receiver to 8.0 MHz.
e. Oscillator Output Test
(10) Adjust capacitor C254 to provide an 8.000
(1) Rotate the indexing fixture switch (fig. 67)
MHz reading on the receiver (or frequency counter).
to 2, and set the slug rack control to 500.
Readjust capacitor C254 for minimum 1-MHz ripple on
the oscilloscope wavetrain.  The remaining 8.0 MHz
(2) On the test fixture, set the LOOP SEL
wavetrain amplitude shall not be less than 0.9 volt peak-
switch to CLOSED, place OSC CONTROL switch S1 to
to-peak.
0, and set OSC CONTROL switch S2 to 50.
(11) Rotate the switch on the indexing fixture
(3) Connect the multimeter rf probe to the
to 6 and set the receiver to 9.0 MHz.
test fixture VFO jack.
(12) Adjust capacitor C256 to provide a 9.000
(4) Read the multimeter; then rotate the
MHz reading on the receiver (or frequency counter).
switch on the indexing fixture to 3, and the OSC
Readjust capacitor C256 for minimum 1-MHz ripple on
CONTROL switch S1 to 1 and read the multimeter
the oscilloscope wavetrain.  The remaining 9.0 MHz
again. Continue the simultaneous advancement of the
wavetrain amplitude shall not be less than 0.9 volt peak-
indexing fixture switch and the OSC CONTROL switch
to-peak.
S1 throughout their range. The multimeter reading shall
not be leas than 1.0 volt at any band position.