| TM 11-5820-509-35
Test
Radio
equipment
control
Test
Performance
Step
settings
settings
procedures
standards
3
a. Set switch on antenna
a. Adjust KILOCYCLES
a. Repeat step 1a.
a. Same as step 1a.
simulator to 11,999 kHz
indicator to 11999; place
position.
OPR-TUNE switch to
TUNE.
b. n/a
b. n/a
b. Immediately return
b. n/a
OPR-TUNE switch to
OPR.
4
a. Same as step 3a.
a. Place XMTR PWR
a. Same as step 1a.
a. Same as step 1a.
switch to HI; then place
OPR-TUNE to TUNE.
b. n/a
b. n/a
b. Immediately return
b. n/a
OPR-TUNE to OPR; and
place XMTR PWR to LO.
4-16. Transmitter Frequency Stability Test
(1) Connect the test equipment to Radio
Receiver-Transmitter RT-671/PRC-47 as shown in
a. Test Equipment and Material.
(2) Connect the primary power source to the
(1) Oscillator TS-382/U
receiver-transmitter.
(2) Dummy Load DA-75/U
(3) Turn on the test equipment and place the
(3) Frequency Counter AN/URM-79/U
POWER-LIGHTS switch on RT-671/PRC-47 to POWER
(4) Output attenuator (fig. 4-5)
ON. Permit the equipment to stabilize at least 5
(5) Blocking capacitor (fig 4-5) 4-6 Primary
minutes before beginning the procedures shown in the
power source: 26.5-volt, dc, 11 amperes approx.
chart below.
b. Test Conditions and Equipment Connections.
Figure 4-5. Transmitter Frequency Stability Test, Equipment Setup
FSK/VOICE switch to VOICE, the XMTR PWR switch to
c. Procedure.
LO, and the OPR-TUNE switch to OAR.
(1) On RT-671/PRC-47, set the
KILOCYCLES indicator to 9900: set CW-
4-14
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |