| TM 11-5820-509-35
Figure 4-4. Transmitter Power Output and Output Meter Sensitivity Tests, Equipment Setup.
AMPLIFIER TUNE and POWER AMPLIFIER LOAD
c. Procedure.
controls on the front of the receiver-transmitter for
maximum deflection on the XMTR OUTPUT meter.
(1) Set the selector switch on the antenna
Use the OPR-TUNE switch to control power amplifier
simulator to the 2000 kHz position.
plate power. Do not permit the power amplifier to
(2) On
RT-671/PRC-47,
set
the
operate for more than a few seconds in the unloaded or
KILOCYCLES indicator to 2000; place CW-FSK/VOICE
off-resonant condition, serious equipment damage can
switch to VOICE; XMTR PWR switch to LO; and OPR-
result. Between each procedural step of the following
TUNE switch to OAR.
chart, resonate the power amplifier output circuit at the
(3) Place the turns-counters of POWER
new operating frequency.
AMPLIFIER TUNE and POWER AMPLIFIER LOAD
controls to the settings recommended on the LOAD-
TUNE chart on the front of the receiver-transmitter.
CAUTION
Before making the following
measurements, resonate the POWER
Test
Radio
equipment
control
Test
Performance
Step
settings
settings
procedures
standards
1
a. Set vtvm RANGE switch
a. Place OPR-TUNE switch
a. Read rf voltage across
a. Vtvm reads not less than
to 30 VOLTS.
to TUNE.
dummy load.
13.7 volts rms.
b. n/a
b. n/a
b. Immediately return
b. n/a
OPH-TUNE switch to
OPR.
c. Set vtvm RANGE switch
c. Place XMTR PWR
c. Read rf voltage across
c. Vtvm reads not less than
to 100 VOLTS.
switch to HI; then place
dummy load.
30.7 volts rms.
OPR-TUNE to TUNE.
d. n/a
d. n/a
d. Immediately return
d. n/a
OPR-TUNE switch to
OPR: then place XMTR
PWR switch to LO
4-10
|