Table 2-4. Troubleshooting, Local Control Unit (cent).
Malfunction
Test  or
Inspection
Corrective Action
6 . TELEPHONE COMMUNICATIONS ARE SENT OUT BUT NOT RECEIVED BY LOCAL CONTROL UNIT
(cent)
2 . Check for defective switch S102 by checking continuity of switch (section A rear, contacts 4
Step
and  1).
If  defective,  replace  (paragraph  2-14).
7 . RADIO SET T R A N S M l T T E R I S N O T E N E R G I Z E D B Y L O C A L C O N T R O L U N I T .
Step 1. Check for defective relay K101 by checking for presence of battery voltage at contact 1.
a. If battery voltage is present, set TEL-REMOTE-RADIO switch to RADIO.
b. Press handset push-to-talk switch and check for continuity between pin C of RADIO
connector  P101  and  ground.
Step 2. Check for defective switch S102 by checking continuity of switch (section A rear, contacts 6 and
8  and  section  B  rear,  contacts  10  and  12).
If  defective,  replace  (paragraph  2-14).
Step 3. Check for defective RADIO connector P101 by checking continuity of all pins.
If  defective,  replace  (paragraph  2-14).
8 . RADIO SET TRANSMlTTER IS NOT ENERGIZED BY REMOTE CONTROL UNIT.
Step 1. Check for defective relay K101 using procedure in malfunction 7, step 1.
If  defective,  replace  (paragraph  2-13).
Step 2. Check for defective resonant relay amplifier by checking for presence of operating voltage at
terminals  3,  4,  and  5  of  component  board  A102.
If  defective,  replace  amplifier  (paragraph  2-13).
Step 3. Check for defective connectors P102 and J104 by checking continuity of connectors
(pins A, D, E, or F).
Replace  defective  connector(s)  (paragraph  2-13).
9 . RADIO SET TRANSMlTTER IS ENERGIZED BY LOCAL CONTROL UNIT BUT SIGNALS ARE NOT
TRANSMlTTED.
Step 1. Check for defective filter FL101 by checking resistance of filter (paragraph 2-5).
If  defective,  replace  (paragraph  2-13).
Step 2. Check for defective switch S102 by checking continuity of switch S102 (section A front,
contacts 11 and 5 and section B rear, contacts 3 and 4).
If  defective,  replace  (paragraph  2-14).
2-17