| TM 11-5820-401-34-3/0967-LP-432-3060
SILICON VERSION A5200A SQUELCH AMPLIFIER ALINEMENT, OLD SQUELCH LEVEL. (CONT)
5-28.
CONTROL AND SWITCH SETTINGS (CONT)
POSITION/SETTING
EQUIPMENT
CONTROL OR SWITCH
OPERATE
OPERATE/OFF/STAND BY
AN/URM-103
EXT MOD
FUNCTION
BAND SWITCH
64.00
RF TUNING
10
DEVIATION RANGE KHZ
LO, 0-10 KUV
RF OUTPUT
Fully counterclockwise
DEVIATION
Adjust until needle on IF UV RF SET TO LINE
RF SET TO LINE
meter is over red line
20 v
LO RF UV
ON
POWER
AN/URM-127
FREQ RANGE MULTIPLIER
x100
73
FREQ RANGE DIAL
x10
ATTENUATOR
Turn clockwise for 2.2-volt reading on panel
OUTPUT CONTROL
ON
FREQ METER
POWER
TRACK
AN/USM-207
DISPLAY
MIN (fully counterclockwise)
(to verify
0.1 v
SENSITIVITY
AN/URM-127
1
GATE TIME
low-frequency
FREQ
FUNCTION
output)
POWER
TRACK
AN/USM-207
DISPLAY
MIN (fully counterclockwise)
(to verify
PLUG IN
SENSITIVITY
AN/URM-103
FREQ
FUNCTION
high-frequency
104 (black knob)
GATE TIME
output)
DIRECT
DIRECT/HETERODYNE
INPUT
0.3 V MAX (both switches to left)
100
FREQUENCY TUNING-MC
5-129
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |