| TM 11-5820-401-34-3/0967-LP-432-3060
5-24. SILICON VERSION A5300A SQUELCH FILTER ALINEMENT. (CONT)
1. Lift R-442/VRC A3000 tray (1). (See test setup diagram
.)
2. Set ME-30(*)/U to 10-volt scale.
3. Connect ME-30(*)/U positive lead to TP5008 (2), and negative lead to ground.
4. Turn AN/URM-103 DEVIATION control clockwise until DEVIATION KHZ meter indicates 8 kHz.
5. Adjust AN/URM-127 FREQ RANGE DIAL to vary frequency above and below 150 Hz while
observing ME-30(*)/U. Stop at frequency that gives highest possible ME-30(*)/U reading.
6. Check and record AN/URM-127 modulating frequency as indicated by AN/USM-207 frequency
counter. if frequency is 150 1Hz, A5300A alinement is satisfactory. If frequency is above
151 Hz, go to step 7; if under 149 Hz, go to step 10.
7. FREQUENCY ABOVE 151 HZ. Turn R5303 (3) counterclockwise slightiy. Reset AN/URM-127
FREQ RANGE DIAL to obtain a peak reading on ME-30(*)/U.
8. Check frequency on AN/USM-207.
9. Repeat steps 7 and 8 until peak ME-30(*)/U reading is obtained at a frequency between 149 and
151 Hz.
10.FREQUENCY BELOW 149 HZ. Turn R5303 (3) clockwise slightly. Reset AN/URM-127 FREQ
RANGE DIAL to obtain a peak reading on ME-30(*)/U.
11.Check frequency on AN/USM-207.
12. Repeat steps 10 and 11 until peak ME-30(*)/U reading is obtained at a frequency between 149
and 151 Hz.
5-118
|