| TM 11-5820-401-34-3/0967-LP-432-3060
5-15. CRYSTAL REFERENCE SYSTEM (CRS) TEST. (CONT)
14. Connect T-connector to frequency counter.
15. Set AN/URM-103 RF OUTPUT control to 125 KUV.
16. Adjust AN/URM-103 RF TUNING control for 42.00-MHz output. Verify frequency on
frequency counter.
17. Set ME-26(*)/U to 3-vdc scale and turn ZERO ADJ for midscaie reading.
18. Connect ME-26(*)/U positive lead to TP3001 (3) and negative lead to ground.
19. Check reading on ME-26(*)/U. Meter should read zero vdc (midscale), with SIight
fluctuation.
NOTE
If ME-26(*)/U reads greater than + 0.32 vdc or less than -0.32 vdc, the CRS is
defective. See the troubleshooting section.
20. Slowly turn AN/URM-103 RF TUNING control to increase output frequency to 42.25 MHz.
Note change in reading on ME-26(*)/U.
21. Slowly turn AN/URM-103 RF TUNING control to decrease output frequency to 41.75 MHz.
Note change in reading on ME-26(*)/U.
NOTE
In steps 20 and 21, ME-26(*)/U should vary smoothly at least + 0.5 vdc and then at least
-0.5 vdc. If not, the CRS is defective. See the troubleshooting section.
22. Proceed to paragraph 5-16, Local Oscillator A1500 Alinement.
5-16. LOCAL OSCILLATOR A1500 ALINEMENT.
PURPOSE. If the local oscillator is operating at the correct frequency, the CRS will not ouput a dc
error signal. This procedure alines the oscillator by tuning its circuits to bring the CRS error signal as
close to zero as possible. The Crystal Reference System Test (paragraph 5-15) must be done prior to
performing this alinement.
TEST EQUIPMENT AND MATERIALS
Signal Generator AN/URM-103
Matching Unit CN-901/U
Frequency Counter AN/USM-207
T-Connector UG-274/U
Power Supply PP-1104(*)/G
Loudspeaker LS-454/U
Test Cable No. 1
Multimeter ME-26(*)/U
5-93
|