A5200 SQUELCH AMPLIFIER ALINEMENT, OLD SQUELCH LEVEL.
3-27.
PURPOSE. This procedure adjusts the receiver sensitivity to the OLD SQUELCH signals which
include internal noise and the received carrier.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Signal Generator AN/URM-103
T-Connector UG-274/U
Frequency Counter AN/USM-207
Loudspeaker LS-454/U
Power Supply PP-1104(*)/G
Voltmeter ME-30(*)/U
Signal Generator AN/URM-127
Maintenance Kit MK-1978P/VRC
TEST SETUP. Connect the equipment as shown in test setup diagram
. Remove R-442/VRC top
cover. (See paragraph 2-7.)
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment as indicated in the following table. When
using alternate equipment, inject 20-v rf at 42 MHz, 7.3-kHz modulation, and deviation as per
alinement requirements.