A5200 SQUELCH AMPLIFIER ALINEMENT, NEW SQUELCH LEVEL. (CONT)
3-25.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment as indicated in the following table. When
using alternate equipment, inject 20- rf at 30 MHz, with 150-Hz modulation, and deviation as per
a l i n e m e n t requirements.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
POWER
ON-RESET
R-442/VRC
BAND
MC-TUNE-KC
30.00
Fully clockwise
VOLUME
NEW ON
SQUELCH
AN/URM-103
OPERATE/OFF/STAND BY
OPERATE
150 Hz
FUNCTION
BAND SWITCH
RF TUNING
30.00
10
DEVIATION RANGE KHZ
LO, 0-10 KUV
RF OUTPUT
DEVIATION
Fully counterclockwise
RF SET TO LINE
Adjust until needle on IF UV RF SET TO LINE
meter is over red line
LO RF UV
20 v
POWER
MK-1978/VRC
ON
AUX RCVR
NORMAL
AUDIO
MUTED
SQUELCH
ON
KEY
RCVE
POWER
AN/USM-207
TRACK
DISPLAY
MIN (fully counterclockwise)
SENSITIVITY
PLUG IN
FUNCTION
FREQ
103 (black knob)
GATE TIME
DIRECT/HETERODYNE
DIRECT
INPUT
0.3 V MAX (both switches to left)
FREQUENCY TUNING-MC
100
ALINEMENT PROCEDURE
NOTE
Check the frequency counter to make sure that the signal generator is outputting exactly
30 MHz. The rf level must be increased temporarily to enable the frequency counter to
display. Adjust the AN/URM-103 RF TUNING control as necessary, reset to 20- rf
level; then disconnect the T-connector from the counter.