| TM 11-5820-401-34-3/0967-LP-432-3060
3-24.
SILICON VERSION A5300A SQUELCH FILTER ALINEMENT. (CONT)
1.
Lift R-442/VRC A3000 tray (1). (See test setup diagram
2.
Set ME-30(*)/U to 10-volt scale.
3.
Connect ME-30(*)/U positive lead to TP5008 (2), and negative lead to ground.
4.
Turn AN/URM-103 DEVIATION control clockwise until DEVIATION KHZ meter indicates
8 kHz.
Adjust AN/URM-127 FREQ RANGE DIAL to vary frequency above and below 150 Hz while
5.
observing ME-30(*)/U. Stop at frequency that gives highest possible ME-30(*)/U
reading.
Check and record the AN/URM-127 modulating frequency as indicated by AN/USM-207
6.
frequency counter. If frequency is 150 1 Hz, A5300A alinement is satisfactory.
If frequency is above 151 Hz, go to step 7; if under 149 Hz, go to step 10.
7.
FREQUENCY ABOVE 151 HZ. Turn R5303 (3) counterclockwise slightly. Reset AN/URM-127
FREQ RANGE DIAL to obtain a peak reading on ME-30(*)/U.
Check frequency on AN/USM-207.
8.
Repeat steps 7 and 8 until peak ME-30(*)/U reading is obtained at a frequency between
9.
149 and 151 Hz.
FREQUENCY BELOW 149 HZ. Turn R5303 (3) clockwise slightly. Reset AN/URM-127 FREQ
10.
RANGE DIAL to obtain a peak reading on ME-30(*)/U.
Check frequency on AN/USM-207.
11.
Repeat steps 10 and 11 until peak ME-30(*)/U reading is obtained at a frequency
12.
between 149 and 151 Hz.
A5200 SQUELCH AMPLIFIER ALINEMENT, NEW SQUELCH LEVEL.
3-25.
PURPOSE. This procedure adjusts the receiver sensitivity to the 150-Hz NEW SQUELCH tone.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Signal Generator AN/URM-103
T-Connector UG-274/U
Frequency Counter AN/USM-207
Loudspeaker LS-454/U
Power Supply PP-1104(*)/G
Voltmeter ME-30(*)/U
Maintenance Kit MK-1978/VRC
TEST SETUP. Connect the eqipment as shown in test setup diagram .
Remove R-442/VRC top
cover. (See paragraph 2-7)
3-118
|