| TM 11-5820-40103403/0967-LP-432-3060
3-15. CRYSTAL REFERENCE SYSTEM (CRS) TEST. (CONT)
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
POWER
R-442/VRC
ON-RESET
BAND
MC-TUNE-KC
30.00
VOLUME
Fully clockwise
SQUELCH
NEW OFF
OPERATE/OFF/STAN D BY
AN/URM-103
OPERATE (allow 15-minute warmup)
FUNCTION
1000 Hz
BAND SWITCH
B
RF TUNING
30.00
DEVIATION RANGE KHZ
10
RF OUTPUT
LO, 0-10 KUV
DEVIATION
Fully counterclockwise
RF SET TO LINE
Adjust until needle on IF UV RF
SET TO LINE meter is over red line
100 v
LO RF UV
POWER
TRACK
AN/USM-207
DISPLAY
MIN (fully counterclockwise)
SENSITIVITY
PLUG IN
FUNCTION
FREQ
103 (black knob)
GATE TIME
DIRECT/HETERODYN E
DIRECT
INPUT
0.3 V MAX (both switches to left)
FREQUENCY TUNING-MC
100
POWER
ON
MK-1978/VRC
AUX RCVR
NORMAL
AUDIO
MUTED
ON
SQUELCH
RCVE
KEY
TEST PROCEDURE
NOTE
30 MHz. The rf level must be increased temporarily to enable the frequency counter to
display. Adjust the AN/URM-103 RF TUNING control as necessary, reset to 100-v rf
Ievel; then disconnect the T-connector from the counter.
3-92
|