| TM 11-5820-401-34-3/0967-LP-432-3060
3-4.
NEW SQUELCH TEST. (CONT)
24. Adjust AN/URM-103 RF TUNING control for 65.00-MHz display on AN/USM-207. To produce
display, see note under step 1 and readjust RF TUNING control until AN/USM-207 indicates
65.00 MHz.
25. Repeat steps 2 through 9.
NEW SQUELCH Test at 75.00 MHz
Change R-442/VRC MC-TUNE-KC switch to 75.00 MHz.
26.
Turn AN/URM-103 RF TUNING control for 75.00-MHz meter indication.
27.
Adjust AN/URM-103 RF TUNING control for 75.00-MHz display on AN/USM-207. To produce
28.
display, see note under step 1 and readjust RF TUNING control until AN/USM-207 indicates
75.00 MHz.
29.
Repeat steps 2 through 9.
3-5.
OLD SQUELCH TEST.
PURPOSE. This test checks the sensitivity of the R-442/VRC squelch modules (A5200, A5300) to
OLD SQUELCH noise components (7300 Hz) at several carrier frequencies. Proper operation of the
squelch modules is verified by CALL lamp response to signal strength at or below a 0.7- rf carrier
level.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Power Supply PP-1104(*)/G
Frequency Counter AN/US M-207
Rf Cables (two) RG-58/U
Maintenance Kit MK-1978/VRC
Signal Generator AN/URM-103
Adapter (T-Connector) UG-274 B/U
3-12
|