Page Title: NEW SQUELCH Test at 41.00 MHz
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-401-34-3/0967-LP-432-3060
3-4. NEW SQUELCH TEST. (CONT)
5. If LO RF UV control setting is more than 0.5 when CALL lamp lights, or if CALL lamp
does not light, see troubleshooting chart 3-3.
6. Remove cable from R-442/VRC ANTENNA port.
STANDARD. R-442/VRC CALL lamp should go out. Remember that without the 150-Hz tone, Relay
K5002 will not be energized to supply the 16 volts necessary to turn on the audio amplifiers; therefore,
the receiver is squelched.
7. If CALL lamp does not go out, see troubleshooting chart 3-3.
8. Reconnect cable to R-442/VRC ANTENNA port.
STANDARD. R-442/VRC CALL lamp should light.
9. If CALL lamp does not light, see troubleshooting chart 3-3.
NEW SQUELCH Test at 41.00 MHz
10. Change R-442/VRC MC-TUNE-KC switch to 41.00 MHz and BAND to
.
11. Turn AN/URM-103 BAND SWITCH to
and RF TUNING control for 41.00-MHz meter
indication.
12. Adjust AN/U RM-103 RF TUNING control for 41.00-MHz display on AN/USM-207. To produce
display, see note under step 1 and readjust RF TUNING control until AN/USM-207 indicates
41.00 MHz.
13. Repeat steps 2 through 9.
NEW SQUELCH Test at 52.00 MHz
14. Change R-442/VRC MC-TUNE-KC switch to 52.00 MHz.
15. Turn AN/URM-103 RF TUNING control for 52.00-MHz meter indication.
16. Adjust AN/URM-103 RF TUNING control for 52.00-MHz display on AN/USM-207. To produce
display, see note under step 1 and readjust RF TUNING control until AN/USM-207 indicates
52.00 MHz.
17. Repeat steps 2 through 9.
NEW SQUELCH Test at 53.00 MHz
18. Change R-442/VRC MC-TUNE-KC switch to 53.00 MHz and BAND to
.
19. Turn AN/URM-103 RF TUNING control for 53.00-MHz meter indication.
20. Adjust AN/URM-103 RF TUNING control for 53.00-MHz display on AN/USM-207. To produce
display, see note under step 1 and readjust RF TUNING control until AN/USM-207 indicates
53.00 MHz.
21. Repeat steps 2 through 9.
NEW SQUELCH Test at 65.00 MHz
22. Change R-442/VRC MC-TUNE-KC switch to 65.00 MHz,
23. Turn AN/URM-103 BAND SWITCH to
) and RF TUNING control for 65.00-MHz meter
indication.