PUT and AF INPUT RETURN ter-
and 10,000 cps must be at least
6 db lower than that in (4) above.
minals on the audio test box. Con-
(7) The ME-30B/U indications at 250,
nect the 10-pin connector on the
3,000, and 6,000 cps must be with-
test box to the AUDIO jack on the
in 2 db of that in (4) above.
rt unit.
c. Broadband Audio Test Procedure.
(2) Connect Variable Attenuator CN-
(1) Remove the rt unit from its case
318/U, the AN/URM-43A, the T-
and set switch S801 to BB. Replace
coaxial connector, the linear de-
the rt unit in its case. (Refer to
tector, and the ME-30B/U.
b. Adjust the TS-382/U to produce a test
T M 11-5820-222-20 for proce-
signal of 0.1 volt at 1,000 cps across the
dure and location of S801.)
(2) Make the connections given in a
150-ohm resistor in the dummy micro-
phone.
above, except omit the dummy
c. Tune the rt unit to 399.9 mc and key
microphone and connect the TS-
it by shorting the RADIO CONT LINE ter-
382/U, through the matching pad
minal to the CONT LINE RETURN termi-
(fig. 119, note 3), to terminals B
nal on the audio test box.
and D of BROAD BAND jack J704.
d. Note the demodulated audio output at
(3) Set the TS-382/U to 1,000 cps.
the linear detector, as indicated in db on
Connect the ME-30B/U across the
the ME-30B/U.
600-ohm resistor in the matching
e. Remove the 1,000-cps signal input
pad (fig. 119, note 3), and adjust
and note the db reading on the ME-30B/U.
the TS-382/U signal level for 0.1
The db reading should be at least 35 db
volt on the ME-30B/U. Record the
below the reading obtained in d above.
TS-382/U output level meter indi-
cation.
(4) Connect the ME-30B/U to the out-
159. Overall Distortion Test
put of the linear detector. Record
a. Make the following connections to the
the level of the demodulated output
rt unit. Use figure 119 as a guide.
signal, in decibels, indicated on the
(1) Connect the TS-382/U through the
ME-30B/U.
dummy microphone to the AF IN-
(5) Set the TS-382/U to 100,250,3,000,
PUT and AF INPUT RETURN ter-
6,000, 10,000, 15,000, and 25,000
minals on the audio test box. Con-
cps and record the ME-30B/U in-
nect the 10-pin connector on the
dication (in db) at the linear de-
audio test box to the AUDIO jack
tector for each frequency.
on the rt unit.
Note. Maintain a constant signal level
(2) Connect Variable Attenuator CN-
from the TS-382/U at the above frequen-
318/U, the AN/URM-43A, the T-
cies by maintaining the TS-382/U output
coaxial connector, and the linear
level  meter  indication  recorded  in  (3)
detector.
above.
(6) The ME-30B/U indications at 100
(3) Connect the TS-723A/U across the
output of the linear detector.
cps must be not more than 5 db
b. Adjust the TS-382/U to produce a test
below that in (4) above.
signal of 0.1 volt at 1,000 cps across the
(7) The ME-30B/U indications at 250,
150-ohm resistor in the dummy micro-
3,000, 6,000, 10,000, 15,000, and
phone.
25,000 cps must be within 2 db of
c. Using the TS-723A/U, measure the
that in (4) above.
harmonic distortion of the 1,000-cps sig-
nal at the output of the linear detector. The
158. Carrier Noise Level
harmonic distortion must not exceed 10
a. Make the following connections to the
percent.
rt unit. Use figure 119 as a guide.
Note. Do not change the input signal level.
(1) Connect the TS-382/U through the
d. Set the TS-382/U frequency to 250,
194