TB 9-2320-387-35-8
10-41. Remove 0.187-inch of insulation from negative (72) and positive (68) wires on power cable (23).
10-42. Attach shrink tubing (69) and terminal lugs (71) and (70) to power cable negative lead (72) and
power cable positive lead (68). (Refer to TM 9-2320-387-24 for terminal connector repair.)
69
70
69
87
.1
0
68
71
87
0.1
72
23
0
3.0
0
1.5
69. SHRINK TUBING MS23054/4-103-0 QTY. 3 INCHES.
70. TERMINAL LUG 7728780 QTY. 1
71. TERMINAL LUG 7728777 QTY. 1
Figure 5-76.
5-66