| TB 9-2320-387-35-5
NOTE
Remove terminal board cover before connecting leads, and
reinstall cover after leads are connected.
22-54. Attach heat shrink tubing (88) and two terminal lugs (86) and (92) to EPLRS power cable negative
lead (91) and EPLRS power cable positive lead (89). (Refer to TM 9-2320-387-24 for terminal
connector repair.)
22-55. Connect EPLRS power cable positive lead (89) to 24-volt terminal board (94), located on cab
enclosure panel (95), with existing nut (87).
22-56. Connect EPLRS power cable negative lead (91) to ground strap (93), located on cab enclosure
panel (95), with existing nut (90).
86
87
88
89
95
~
94
93
92
90
88
91
86. TERMINAL LUG 7728780 QTY. 1
88. SHRINK TUBING MS23053/4-302-0 QTY. A/R
92. TERMINAL LUG 7728777 QTY. 1
Figure 5-93.
5-68
|