| TB 9-2320-387-35-2
NOTE
Remove terminal board cover before connecting leads and
reinstall cover after leads are connected.
13-34. Attach heat-shrink tubing (74) and two terminal lugs (72) and (79) to power cable negative
lead (78) and power cable positive lead (75). (Refer to TM 9-2320-387-24 for terminal connector repair.)
13-35. Connect power cable positive lead (75) to 24V terminal board (81), located on cab
enclosure panel (82), with existing nut (73).
13-36. Connect power cable negative lead (78) to ground strap (80), located on cab enclosure panel (82),
with existing nut (77). Secure leads (75) and (78) together with tiedown strap (76).
73
72
82
74
76
75
~
81
77
80
72.
TERMINAL LUG 7728780 QTY. 1
74.
SHRINK TUBING MS23053/4-302-0 QTY. A/R
76.
TIEDOWN STRAP MS3367-1-0 QTY. A/R
78
79.
TERMINAL LUG 7728777 QTY. 1
79
74
Figure 5-62.
13-37. Route remaining cables to FBCB2 integrated rack (83) using one clamp (85), existing screw (88),
lockwasher (87), and washer (86).
13-38. Route cables along bar (89) to top of FBCB2 integrated rack (83) with two tiedown straps (84).
83
89
88
87
86
85
84
84.
TIEDOWN STRAP MS3367-1-0 QTY. A/R
85.
CLAMP MS21333-104 QTY. 1
87.
LOCKWASHER MS35338-44 QTY. 1
88.
SCREW B1821BH025C088N QTY.
Figure 5-63.
Change 1
5-48
|