| TB 9-2320-280-35-6
Section X. FBCB2 COMPONENTS INSTALLATION
NOTE
SINCGARS model AN/VRC-92F shown.
10-1. Remove paint from vicinity of four holes (8) on integrated rack (7) and both sides of four holes (10)
on CPU isolation kit (4). Apply anti-seize compound as required.
10-2. Install CPU isolation kit (4) on integrated rack (7) with three capscrews (3), washers (2), and
lockwashers (1), leaving open holes (8) and (10).
10-4. Install CPU (6) on CPU isolation kit (4) with two existing fastener guards (5).
10-5. Fabricate ground strap (13) from 8.00-in. length of braided wire and two terminal lugs.
10-6. Install ground strap (13) on CPU ground stud (17) with existing washer (14), lockwasher (15), and
wingnut (16).
10-7. Install ground strap (13) on CPU isolation kit (4) and integrated rack (7) with capscrew (11),
washer (2), and two lockwashers (12).
3
4
2
5
1
6
5
6
10
10
4
11
2
17
7
16
12
14
10
15
9
8
13
1.
LOCKWASHER MS35338-44 QTY. 3
11. CAPSCREW B1821BH025C125N QTY. 1
2.
WASHER 2436161 QTY. 4
12. LOCKWASHER MS45904-68 QTY. 2
3.
CAPSCREW B1821BH025C100N QTY. 3
13. CPU GROUND STRAP
4.
CPU ISOLATION KIT 872826-2 QTY. 1
BRAIDED WIRE AA59569F30T0375 QTY. A/R
6.
CPU 881292-1 QTY. 1
TERMINAL LUG MS20659-141 QTY. 2
Figure 5-23.
Change 1
|