 |  TB 9-2320-280-35-5 NOTE PLGR power cable positive lead insulation is ribbed. 13-3. Attach shrink tubing (6) and terminal lugs (4) and (10) to PLGR power cable negative lead (9) and PLGR power cable positive lead (7). (Refer to TM9-2320-280-20 for terminal connector repair.) 13-4. Attach PLGR power cable positive lead (7) to 24-volt terminal board (12) located on cab enclosure panel (13) with existing nut (5). 13-5. Attach PLGR power cable negative lead (9) to ground strap (11) located on cab enclosure panel (13) with existing nut (5). 13-6. Coil excess positive and negative power leads, place beneath ground strap, and secure with tiedown strap (8). 13-7. Install right side tunnel insulation. (Refer to TM 9-2320-280-20.) 5 4 6 13 7 8 ~ 12 11 5 10 9 6 4. TERMINAL LUG  7728780  QTY. 1 6. SHRINK TUBING  MS23053/4-302-0  QTY. A/R 8. TIEDOWN STRAP  MS3367-1-0  QTY. A/R 10. TERMINAL LUG  7728777  QTY. 1 Figure. 5-31. 5-24 | 
| 