Section XII. PLGR BRACKET INSTALLATION
NOTE
Perform steps 12-1 through 12-4 for AN/VRC-92F only.
Tiedown anchors may not be installed. If tiedown anchors are not
installed, use existing hole for measurements in step 12-1.
Ensure mounting holes for PLGR bracket are completely on flat
surface of cargo floor raised rib.
12-1. Using PLGR mount (1) as template, mark and drill two 0.390-in. diameter holes (5) in cargo
floor (7).
12-2. Install two inserts (6) in holes (5) in cargo floor (7).
12-3. Attach PLGR mount (1) to cargo floor (7) with two capscrews (2), lockwashers (3), and washers (4).
12-4. Install PLGR bracket (10) on mount (1) with four screws (11), lockwashers (9), and plain-assembled
nuts (8).
2
8
3
4
9
10
1
7.50
~
1.50
1
5
6
7
11
8.
PLAIN-ASSEMBLED NUT 9422771 QTY. 4
1.
PLGR MOUNT 12480576 QTY. 1
9.
LOCKWASHER MS35338-43 QTY. 4
2.
CAPSCREW B1821BH025C100N QTY. 2
10.
PLGR BRACKET 986-0645-001 QTY. 1
3.
LOCKWASHER MS35338-44 QTY. 2
11.
SCREW MS35206-264 QTY. 4
4.
WASHER 2436161 QTY. 2
6.
INSERT 12446871-2 QTY. 2