| AN/TRC-36 Radio Relay Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/TRC-36 is a transportable VHF/UHF-FM radio set which
Frequency: 50 - 1875 MHz
Power: 10 120 W
the different frequency bands.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
Exclude personnel to a distance of 6.3 m from the antenna. The height of the antenna
normally precludes the potential for personnel exposure to RFR.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Specify use of dummy loads for maintenance operations.
REFERENCES: TM 11-5820-287-12
AN/TRC-68A Radio Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/TRC-68 is a fixed station VHF/UHF-AM radio set that
Frequency: 225 400 MHz
Power: 16 W PEP
utilizes a discone antenna with two radiator assemblages.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
Exclude personnel to a distance of 50 cm from the antenna.
RF shock/burn .....................
Observe standard RF shock precautions. Do not touch antenna when energized.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 11-5820-222-10
Equipment - 108
|