AN/PEQ-2A Target Pointer Illuminator/Aiming Light (TPIAL)
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/PEQ-2A is a target illuminator/aiming light.
Wavelength: 820 - 860 nm
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Laser Classification ............
This system contains a Class 3b laser and requires an established laser safety program to
ensure its safe use. Develop a written Local Standing Operating Procedure (SOP) IAW
guidance provided in this TB.
Hazard distance .................
Do not permit personnel to view the laser from within the beam at distances less than 25 m
for unaided viewing or 160 m when viewing the laser through magnifying optical
instruments.
Ocular injury ....................
Avoid direct exposure to beam. Use protective eyewear that filter at 800-860 nm with
minimum OD of 0.5.
Outdoor range operations .....
Eliminate all specular surfaces (man made and natural) capable of producing potentially
hazardous reflections. Control unauthorized personnel access to controlled area. Use only
on an approved laser range or training area. Appoint a qualified Laser Range Safety
Officer. The "Safety Block" should be installed for all exercises, unless use of the
tactical/high power mode is required.
Other...............................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
AN/PPM-4 Test Set Beacon
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/PPM-4 is a low-powered test set which provides
Frequency: X band: 9.3 GHz
Power: 2 mW
simulated interrogation signals to the AN/PPN-20 Beacon
Ku band: 16.2 GHz
PEP 1 W
Transponder and evaluates response to those signals.  It
utilizes horn type antennas.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is not able to produce potentially hazardous PDLs in excess of the safety
standard and is not subject to radiation protection control.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Equipment - 79


Privacy Statement - Press Release - Copyright Information. - Contact Us