| AN/MPQ-51 HAWK Range Only Radar (ROR\IROR)
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/MPQ-51 is part of the HAWK Air Defense System. It
Frequency: CLASSIFIED
Power: CLASSIFIED
provides target range information for the system. The ROR
antenna is a 1.22 m parabolic reflector which operates in a
continuous scan only mode.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB).
Hazard distance from antenna ....
Exclude personnel to a distance of 45 m from the antenna. Do not direct the main beam
toward potentially occupied areas. With the antenna positioned at a fixed positive
elevation angle (+0 mils), no hazard exists for personnel on level terrain.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 9-1425-525-12-4
AN/MPQ-53 PATRIOT Missile System
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/MPQ-53 replaces the HAWK Air Defense System. It
Frequency: CLASSIFIED
Power: CLASSIFIED
provides (Phased Array Tracking to Intercept Of Target (PATRIOT)).
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB). Prohibit fixed beam operation of the main beam.
Hazard distance from antenna ....
Exclude personnel to a distance of 120 m from the antenna. Do not direct the main beam
toward potentially occupied areas. Prohibit personnel from occupying the roof, ladder,
and the door-platform work areas of the radar system during operation. Exclude
personnel to within 2 m of the sides of the radar system. The feed horn area in front of
the main beam is extremely hazardous and can cause serious injury. Exclude personnel
from this area.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Test interlocks periodically. Publish detailed SOPs for operation and maintenance.
Specify use of dummy loads during maintenance operations.
REFERENCES: TM 9-1430-600-12; TM 9-1430-601-10
Equipment - 67
|