|
| AN/MPQ-49 Forward Area Acquisition Radar (FAAR) Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/MPQ-49 is a forward area alerting radar set equipped with an IFF for
locating and identifying aircraft.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
In the nonscanning mode, this system is able to produce potentially hazardous PDLs in
excess of the safety standard. Establish a Nonionizing Radiation Protection Program
(IAW guidelines provided in this TB). In the scanning mode, this system is not able to
produce potentially hazardous PDLs in excess of the safety standard.
Hazard distance from antenna ....
In the nonscanning mode, exclude personnel to a distance of 7.5 m from the antenna.
Exclude personnel from the shelter roof when the antenna is in its lowest operational
position.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 9-1430-588-10
AN/MPQ-50 HAWK Pulse Acquisition Radar (PAR\IPAR)
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/MPQ-50 is the Pulse Acquisition Radar (PAR) of the
Frequency: CLASSIFIED
Power: CLASSIFIED
HAWK Air Defense System. It provides target range and azimuth
information for the system. The PAR antenna is a 1.6 x 6.7 m
cosecant-squared, prime-fed, parabolic reflector which operates in a
continuous scan only mode.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
In the nonscanning mode, this system is able to produce potentially hazardous PDLs in
excess of the safety standard. Establish a Nonionizing Radiation Protection Program
(IAW guidelines provided in this TB). In the scanning mode, this system is not able to
produce potentially hazardous PDLs in excess of the safety standard.
Hazard distance from antenna ....
In the nonscanning mode, exclude personnel to a distance of 53 m from the antenna.
Maintain visual surveillance of the fixed-beam controlled zone. Exclude personnel from
the shelter roof when the antenna is in its lowest operational position.
Open/cracked waveguides .......
All open waveguides and the feed horn aperture produce potentially hazardous PDLs
within 1.0 m. Exclude personnel from these areas and do not permit operation of this
system with any cracked, broken or open waveguide. Exclude personnel from the area
on top of the PAR antenna, between the antenna feed and the reflector.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
The stabillitron tube in the transmitter circuit can produce X-radiation.
REFERENCES: TM 9-1425-525-12-4
Equipment - 66
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |