| AN/FPS-71 Radar Set
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/FPS-71 is a radar system that is interlocked such that with the antenna
stationary, the set is operated at reduced power.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
At full power and while scanning, this system is able to produce PDLs in excess of the
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
Exclude personnel to a distance of 85.4 m from the antenna.
Open/cracked waveguides .......
The area between the feed and the reflector and any open waveguide produce potentially
hazardous PDLs. Periodically inspect waveguides for cracks or leaks and replace
suspect waveguides.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
There is a potential x-ray hazard inside transmitter cabinet. Instruct personnel to operate
system only with transmitter cabinet doors closed.
REFERENCES: TM 11-5840-252-12
AN/FRC-154 (V) 1-28 Radio Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/FRC-154 is a microwave dual-channel, full duplex transceiver.
Frequency: 4.4 5.0 GHz
Power: 1.0 W
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is not able to produce potentially hazardous PDLs in excess of the safety
standard.
Open/cracked waveguides .......
All open waveguides and feed horn outputs produce potentially hazardous PDLs.
Exclude personnel to a distance of 6 cm from any open waveguide.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 11-5820-792-14
Equipment - 36
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |