| TB 11-5820-890-12
CHAPTER 3
OPERATOR MAINTENANCE
SUBJECT
PARAGRAPH
PAGE
LUBRICATION INSTRUCTIONS ........................................................................................................3-1
OPERATOR TROUBLESHOOTING PROCEDURES ........................................................................3-2
GENERAL MAINTENANCE AND PREVENTIVE MAINTENANCE PROCEDURES .........................3-3
VISUAL INSPECTION.........................................................................................................................3-4
CLEANING ..........................................................................................................................................3-5
TOOLS AND TEST EQUIPMENT .......................................................................................................3-6
BATTERY REPLACEMENT ................................................................................................................3-7
OPERATOR'S MAINTENANCE PROCEDURES .............................................................................3-8
FULL FUNCTION ANCD .....................................................................................................................3-9
USER/OPERATOR PARTS REPLACEMENT PROCEDURES ........................................................3-10
BATTERY ...........................................................................................................................................3-11
CIK......................................................................................................................................................3-12
3-1. LUBRICATION INSTRUCTIONS.
No lubrication is required for the ANCD.
3-2. OPERATOR TROUBLESHOOTING PROCEDURES.
MALFUNCTION
POSSIBLE CAUSE
CORRECTIVE ACTION
No display
On/Off key not depressed
Press On/Off key
No display
Defective/dead battery
Change battery
Low battery indicator on
Low battery
Change battery
Low battery Indicator on or
Battery contact defective or
Clean contacts or return unit
no display
corroded contacts
to next level of maintenance
ANCD will not transfer data
Fill connector damaged or
Clean fill contacts first,
corroded
replace unit if connector
damaged
ANCD will not transfer data
Fill cable damaged or
Clean contacts first, replace
corroded
cable if suspected defective,
also check cable connection
ANCD displays error
Internal hardware/software
Follow full function ANCD
message
troubleshooting procedures.
3-1
|