8. Remote ControI Operations. The Remote Control Unit (RCU) C-11561 may be used in place of the RT
in a SINCGARS radio system to allow the radio set and antenna to be placed at distances up to 4 km from
the local system. Interoperability between the DMD and the RCU is the same when the DMD is connected
to an RT. Table 8-1 provides the switch settings for the radio set and the RCU for remote control operation.
RADIO SET
RCU
SWITCH
REM
FUNCTI0N
SQ ON
N/A
SC or FH
MODE
N/A
TF
DATA
PT
CT
COMSEC
*
N/A
OFF
Table 8-1. RCU Settings for Remote Operation