TB 11-5820-890-10-12
6.
Switch Settings and Initialization. The following tables provide the necessary switch settings and communication
parameters for interoperability. Initialize the for communication as shown in Table 6-2. Verify the switch settings for
both the radio and the lightweight TACFIRE; then establish communication on the net.
SWITCH
ICOM RADIO
NON-ICOM RADIO
FUNCTION
SQ ON
SQ ON
MODE
SC or FH
SC or FH
DATA
TF
AD2
(TSEC/KY-57) ON
COMSEC
CT
CT
*
OFF
N/A
Table 6-1. SINCGARS Radio Set
TONE PAIR
1200/2400 Hz
XMIT BLOCK:
SINGLE
XMIT RATE:
1200
.7
(1.4 or greater when
operating with PSG-5)
KY:
OFF
MODEM:
-18 dbm
Table 6-2. Lightweight TACFIRE (Recommended)