| MWO 11-5821-260-30-1
Table 1. Radio Set Electrical Test -- Continued
Test equipment
Equipment under test
Step
Test procedure
Performance standard
control settings
control settings
No.
Set the radio set func-
Same as step 1.
Same as step 1.
5 ohms (max).
8
tion switch to D/F and
set the maintenance kit
RADIO TEST switch to
position 8. Set the
maintenance kit DC
POWER circuit breaker
to OFF. Measure the
homing enable line con-
tinuity horn maintenance
kit connector J18 to
ground with the
17
|