Click here to make tpub.com your Home Page

Page Title: AN/GRC-144(V)4 Output Power Test at 14.4 to 15.0 GHz and Power Alarm Calibration
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-695-35
3-76.
AN/GRC-144(V)4 Output Power Test at 14.4 to
15.0 GHz and Power Alarm Calibration
Radio Set AN/GRC-144(V)4 output power test 14.4 to 15.0
GHz assumes that the T-1054(P)A/GRC-144 output power
test has been performed and all performance standards are
in accordance with paragraph 3-72.
a. Test Equipment and Materials.
(3) Open waveguide connection at Converter-
Multiplier CV-3633/GRC-144(V) ANT J4 output and first
shelter waveguide connection by removing screws that
(1) Thermister Mount, Hewlett-Packard P486A
secure waveguide and the CV-3633/ GRC-144(V) together.
(2) Power Meter, Hewlett-Packard 432A
(4) Move the waveguide to a safe location.
(3) Attenuator, Waveline 707-20
CAUTION
b. Test Connections and Conditions.
Do not support test equipment by
waveguides.  Test equipment must be
NOTE
properly supported.
NOTE
To perform the AN/ GRC-144(V)4 output
power test, the waveguide connection
Locate the test equipment close to the
at Converter Multiplier CV-3633/' GRC-
CV-3633/ GRC-144(V) to permit proper
144(V) 3A7J4 ANT waveguide flange
interconnection.
must be opened.
(5) Interconnect
the
test
equipment
in
(1) Record the T-1054(P)A/GRC144(V) and CV- accordance with the test setup shown in figure 3-37.
3633/GRC-144(V) filters 3A3 and 3A4 operating frequency
and dial settings respectively.
c. Initial Test Equipment Calibration.
Turn on the test equipment and allow a 30 minute warmup
NOTE
period. Use the following technical manual procedures to
zero the test equipment.
Disregard  status  panel  waveguide
switch FREQUENCY BAND IN USE and
Item
Technical Manual
transmitter WAVEGUIDE SW indicator
alarms.
Power Meter, Hewlett
Packard HP 432A
Attenuator, Waveline
(2) Insure that transmit waveguide switch is set
707-20 (prepare a
to the 15 GHz TEST (TO LOAD) position. For the
AN/GRC-144(V)4 optional configuration, insure that Switch, calibration chart for
Waveguide SA-1679/GRC is set to{ the TO LOAD (TEST)  the attenuator at 14.4
to 15.0 GHz at 0.1 GHz steps),
position.