| TM 32-5895-206-10
Table 3-2. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. UNIT FAILS TO ERASE OLD SIGNAL WHEN RECORDING ON
USED TAPE.
Step 1. Erase switch in OFF position.
Erase switch is accessed below the cassette
on the unit's right side.
6. VOICE/MICROPHONE NOTATION DOES NOT WORK.
Step 1. Output from receiver too high.
Reduce RF or VOL setting on receiver.
3-22
|