(4) Install 12 fresh BA-30 batteries. Be sure to
observe polarity markings on battery compartment cover.
(5) Reinstall battery compartment cover. Be sure to
align pins properly.
b. Recorder/Reproducer AN/PNH-7 with Battery Assembly
BA-522/PNH-7. Approximate battery life: 8 operating hours. Set
the mode selector switch to the REPRODUCE position. Press
the BAT TEST switch and observe the LEVEL meter. If the
meter does not read in the green (GOOD) range, replace the
batteries as follows:
(1) Set the mode selector switch to OFF. Disconnect
cords from recorder/reproducer.
(2) Unlatch two straps holding recorder/reproducer
and attached battery assembly to packboard.
Remove complete assembly.
(3) Remove battery compartment cover from battery
assembly as shown in figure 2-9.
(4) Remove discharged batteries.
Dispose of
discharged nonrechargeable BA-30 batteries. Save discharged
rechargeable batteries (not normally used).