Click here to make tpub.com your Home Page

Page Title: Synthesizer Test Tray A3, Trouble Localization Chart (cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-6625-847-12
Step
Control setting and
Performance standard and
No.
Operation of test
operation of equipment
references
equipment
b. Frequency standard
Module 1A3, RT-662/
GRC.
c. 10 and 1 kc synthesizer
Module 1A4, RT-622/
GRC.
d. Frequency divider
Module 1A6, RT-662/
GRC.
e. Translator Module 1A8,
RT-662/GRC.
f. Mc synthesizer Module
1A9, RT-/GRC.
9
Set test set SERV SEL switch
Tray A3 POWER indicator il-
to STBY, and tray AS POWER
luminates.
switch to ON.
10
If operating from a cold start,
allow 15-minute warmup time
for equipment stability. If
equipment has been warmed up
within the last hour, 5-minute
warmup time is sufficient.
11
Connect AM/PSM-across
Adjust tray AS POWER ADJ
AN/PSM-indicates voltage
tray AS POWER IN-
control from fully counter-
varying from minimum 0 volt
PUTS VAR test connector
clockwise to fully clockwise.
dc to maximum +26 volts dc;
and POWER INPUTS
set to +20 volts dc (para
(ground) test connector.
4-21, item No. 4).
12
Disconnect AN/PSM-6.
13
Connect AN/URM-145
Set 10&1KC SYNTH OUTPUT
Observe that output increases
to tray A2 10&1KC
AMPL switch to ON, and ad-
as adjustment is made clock-
SYNTH OUTPUT 7.1
just 10&1KC SYNTH OUT-
wise (para 4-21, item No. 5).
MC connector.
PUT VOLT ADJ control from
fully counterclockwise to fully
Caution: Adjust AN/
clockwise. Return 10&1KC
URM-145 to scale above
SYNTH OUTPUT VOLT ADJ
1 volt, and readjust ac-
control from fully counterclock-
cordingly to avoid damage
wise to fully clockwise. Return
to instrument.
10&1KC SYNTH OUTPUT
VOLT ADJ control to mid-
range.
14
Disconnect AN/URM-145
from 10&1KC SYNTH
OUTPUT 7.1 MC con-
nector.
15
Connect AN/URM-145 to
Set tray A3 10&1KC SYNTH
Observe that the output increases
tray AS 10&1KC SYNTH
SYNTH OUTPUTS AMPL
as the adjustment is made
OUTPUTS connector.
switch to ON, and adjust
clockwise (para 421, item
Caution: Adjust AN/
10&1KC SYNTH SYNTH
No. 6).
URM-145 to scale above
OUTPUTS VOLT ADJ con-
1 volt, and readjust ac-
trol from fully counterclock-
cordingly to avoid damage
wise to fully clockwise. Return
to instrument.
10&1KC SYNTH SYNTH
OUTPUTS VOLT ADJ control
to midrange.
16
Disconnect AN/URM-145
from 10&1KC SYNTH
SYNTH OUTPUTS
connector.
4-13