| TM 11-6625-847-12
Figure 4-2. Synthesizer test tray A3, trouble localization test equipment.
4-19.
Common Module Tray A2, Trouble Isolation Chart
Item
No.
Trouble symptom
Probable trouble
Checks and corrective measure
POWER indicator lamp
a. Defective external 27-volt
a. Higher category repair re-
will not illuminate
dc power supply.
quired.
b. Improper seating of input
b. Tighten power connector.
power connector.
c. Defective test set fuse-------------------------
d. Defective indicator light ----------------------
e. Defective POWER switch -------------------
e. Higher category repair re-
quired.
f. Higher category repair re-
f. Defective test set SERV SEL
switch. quired.
2
When AN/PSM-6 dc tests
a. Improper seating of input
a. Tighten power connector.
leads are connected to
power connector.
RCVR IF test points
b. Defective RCVR IF TEST
b. Higher category repair re-
HI and LO, voltage
SELECTOR switch.
quired.
varies more or less than
limits of 29 to 31 volts
dc.
3
When RCVR IF TEST
a. Improper seating of input
a. Tighten power connector.
SELECTOR switch is
power connector.
placed at 2, and RCVR
b. Defective RCVR IF TEST
b. Higher category repair re-
IF GAIN control is ro-
SELECTOR switch.
quired
tated from fully counter-
c. Defective RCVR IF RF
c. Higher category repair re-
clockwise to clockwise,
GAIN control.
quired.
voltage varies more or
less than limits of 0.35
to 2.5 volts dc.
4-10
|