| TM 11-6625-847-12
Control, indicator, or connector
Function
PA METER TEST connector --------------------------------
Mutipin connector for electrical interconnection of front panel
assembly, AM-3349/GRC-106, and tray A4.
CONTROL test connector ------------------------------------
Multipin connector for electrical interconnection of antenna
coupler assembly input connector, and tray A4.
PA METER TEST ANTENNA LOAD/TUNE --------------
Test point for measuring antenna load/tune voltage.
test connector.
PA METER TEST ALC METER test connector----------
Test point for measuring ALC meter voltage.
PA METER TEST (ground) test connector ---------------
Ground test point for voltage measurements
INPUT CLURRENT HI test connector ---------------------
Test point for input current measurements of dc-to-ac inverter
assembly, AM-3349/GRC-106.
INPUT CURRENT LO test connector ---------------------
Test point for input current measurements of dc-to-ac inverter
assembly, AM3349/GRC-106.
TEST SELECTOR LO test connector ---------------------
Test point for voltage measurements of dc-to-ac inverter
assembly, AM-3349/GRC-106.
TEST SELECTOR HI test connector ----------------------
Test point for voltage measurements of dc-to-ac inverter
assembly, AM-3349/GRC-106.
PA METER TEST GRID DRIV.E test connector --------
Test point for measuring grid drive voltage.
Connector ---------------------------------------------------------
Multipin connector for electrical interconnection of dc-to-ac
inverter assembly, AM3349/GRC-106.
Figure 3-5 (1). Converter and control tray A4, controls, indicators, and connectors.